Beachwood, Ohio

Get Your Quote Today



VIP Plumbing Inc. Beachwood, Ohio



Recent Beachwood, Ohio by VIP Plumbing Inc.

Bradford White C-DW2-504T10FBN Combi2 Energy Saver Gas Water Heater System

BEACHWOOD, OH
05-19-2015

Moen faucets

Unisex bathroom Moen flushometer that was not working properly. On first trip tried to replace the batteries and it seemed to work but then shortly after that if failed again. On the next trip we returned with a new unit from Moen and replaced the sensor head. It is now working good.
BEACHWOOD, OH
10-29-2011

InSinkErator b5xp Garbage Disposer

Installed a new Badger 5XP disposal on main kitchen sink. Re piped under the kitchen sink and added an air admittance valve. Sink was draining slow and the piping underneath was kind of a mess. Piping is now cleaned up and drain good. Installed owner supplied kitchen faucet.
BEACHWOOD, OH
10-29-2011

Rheem 82SV20-2

20 gallon electric water heater was leaking in the ceiling. Remove a Bradford White 20 gallon electric tank and replaced it with a Rheem 20 gallon tank. Model #81VP205 Serial #RH0311607044
BEACHWOOD, OH
09-20-2011

Navien NR-240A Condensing Tankless Water Heater W/ Circ

Navien tankless water heater was reading an error code of 12 that indicates a flame failure. Cleaned the flame rod and senor to resolve the problem. Spoke with Navien technical support and they thought this was a short term fix and the unit may need replaced for all the problems they have had.
BEACHWOOD, OH
09-20-2011

Navien NR-240A Condensing Tankless Water Heater W/ Circ

To try and help the tankless water heater keep the storage tank up to temperature we installed a Aqua Stat that can be adjusted to a greater temperature range for when the unit turns off and on. Installed a Honey well L6006C surface mounted aqua stat. There was no charge for this service call or for the parts.
BEACHWOOD, OH
09-20-2011

Navien NR-240A Condensing Tankless Water Heater W/ Circ

Called out to repair Navien tankless water heater for no hot water. Found that the circulating pump had been turned off. This may have caused the cold water to bleed through the pump and temper down the hot water. Installed a 3/4 check valve on the line after the pump to prevent backflow. Gave two different options for a properly installed system. One option was for a 120 gallon storage tank using the Navien strictly to the tank. Second option was to remove the electric and tankless units and install a commercial 100 gallon Rheem tank.
BEACHWOOD, OH
09-20-2011

Navien NR-240A Condensing Tankless Water Heater W/ Circ

Trouble shot Navien commercial unit that was not getting enough hot water in conjunction with the electric 80 gallon water heater. Feel the part of the problem is the way the unit is piped. We will change the circulating pump piping around and install a aqua stat to limit when the pump runs. The other problem is the constant on and off with water every 10 to 15 seconds. The unit does not have time to get up to temperature before it is shut off again. Hopefully the pump will cause the unit to run and keep the storage tank hot. While doing this work we noticed the water flow senor would stick once in a while so we installed a new one.
BEACHWOOD, OH
09-20-2011